You have no items in your shopping cart.
Shop Catagories

You have no items in your shopping cart.

| How It Works | Start-up mode: When the mains supply is initially connected to the PIR occupancy switch it goes through its Start-up Mode. This means it switches on for about 1 minute, then switches off and enters its Operating Mode. If a manual wall switch is feeding the PIR occupancy switch (see wiring diagrams on appropriate product pages) then it will go through the Start-up Mode each time the wall switch is switched on. By wiring the manual wall switch in the alternative position, the supply to the PIR occupancy switch is uninterrupted and it remains in Operating Mode. It does not go through its Start-up Mode each time the wall switch is switched on. |
|---|---|
| Specification | Detection zone: 360º Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 100 to 1000 lux, and inactive Loading: up to 6 amps (1500W) of resistive, fluorescent or inductive lighting loads, or up to 1 amp (250W) of fans Dimensions (mm): 72 diameter x 68 |
| Manufacturer | The Energy Saving Company |